Reference Data

The Reference Data window (menu Help → Reference Data, shortcut Ctrl-R) collects the small reference tools that do not belong to any particular experiment: a periodic table with nuclear data, an experiment-time planner and a set of programmable calculators. The window is non-modal — it can stay open next to the Experiment Editor while an experiment is running.

Tab

Contents

Periodic Table

Clickable periodic table. Selecting an element lists its isotopes with nuclear spin, gn, Larmor frequency at the chosen magnetic field, natural abundance and quadrupole moment.

Experiment Planner

Estimates the duration of an experiment from the number of points in up to three dimensions, the number of shots, the repetition time and a percentage overhead.

Formulas

The programmable calculator described below.

Introduced in version 3.8.5

A formula is a set of named scalar variables tied together by one equation — for example the EPR field, the microwave frequency and the g-factor. The tree on the left lists all available formulas grouped by topic; selecting a leaf builds the input panel for that formula on the fly and shows the formula's description in the Help box underneath.

Every variable occupies one row of the panel: a caption, a unified edit control carrying the variable's unit, range and resolution, and — for variables that can be solved for — a = toggle button. The pressed toggle marks the output: the value that is recalculated whenever any other field on the panel changes. Press a different toggle to invert the calculation and solve for that variable instead. Variables shown read-only carry no toggle; they are derived read-back values (for example beta in the Qoc formula, or the dBm reading next to a power in watts) and are recomputed after every change.

Nothing about a formula is hard-coded in the program: the panel, the units, the limits and the equations all come from a data description (see below). Adding a formula therefore requires no new version of SpecMan4EPR.

Each formula remembers the values you entered, the variable solved for and its option, also across restarts (section [Formulas] of SpecMan4EPR.ini; only values that differ from the defaults are kept). Reset this formula to its defaults in the right-click menu of the tree brings back the built-in values.

User formulas are read at start-up from the optional file cfg\formulas.json next to SpecMan4EPR.exe. The file is merged after the built-in list: it never replaces the built-in formulas, it only appends to them, and a missing or malformed file is silently ignored. Formulas with a group that already exists join that branch of the tree.

The file is a single object with one formulas array. Each entry describes one tree leaf:

Key

Meaning

group

Caption of the tree branch the formula is filed under. Entries sharing a group are collected under one node.

name

Required. Caption of the tree leaf. An entry without a name is skipped.

help

Text shown in the Help box when the formula is selected.

constants

Object of named numeric constants (for example { "gamma": 1.401e6 }) visible to every expression of this formula.

vars

Required. Array of variables, one panel row each, in display order. An entry with no usable variable is skipped.

Each element of vars describes one variable. All keys except sym are optional; defaults are given in brackets.

Key

Meaning

sym

The name the variable has inside expressions. Keep it short and unique within the formula (B, Qcc, dBm, ...).

caption

Label displayed above the edit control.

unit

Unit shown by the edit control. Standard SI prefixes may then be typed into the field (see Unified Edit Control).

value

Initial value [0].

lsd

Last significant digit, as a power of ten — it fixes how the value is displayed and rounded [0].

min, max

Allowed range of the input [±1e30].

inc, minInc

Spin-button step and the smallest step the modifier keys can reach [1 and 1e-6].

solve

The expression that produces this variable from the others — the equation already rearranged for it. Its presence is what makes the variable computable.

derived

true marks a read-only read-back value: no toggle, recomputed after every change [false].

How the role of a variable is decided. No symbolic inversion is performed — every solvable variable carries its own rearranged expression, so the three roles follow directly from the two keys above:

Keys

Role

no solve

Input — editable, never recomputed, no toggle button.

solve, derived false

Output — joins the toggle group; the one selected toggle is recalculated when another field changes.

solve, derived true

Derived — read-only, recomputed on every change, in declaration order.

The toggle initially pressed is the last output variable declared. A formula with no output variable at all is a pure forward calculator: only its derived rows are updated.

The solve expressions are evaluated by a small arithmetic parser belonging to the calculator itself — it is not the PPL expression engine and knows nothing about devices or experiment variables.

Element

Supported

Operators

+ - * /, power ^ (right-associative), unary minus, parentheses.

Functions of one argument

sqrt log log10 exp sin cos tan asin acos atan abs sign floor ceil

Functions of two arguments

pow atan2 min max

AWG hrepeat body

Introduced in version 3.8.17

awgbody(dt, step, minblock, f, tol): the number of samples (sampling time dt) in the shortest hrepeat body an AWG plays as one looped block — a multiple of step samples, at least minblock — that holds a whole number of periods of the carrier frequency f to within tol degrees per pass (0: exact). Every pass of a hardware loop is a copy of the first, so the carrier phase slips by the fraction of a period left over at each pass. The built-in formula AWG → hrepeat body for a carrier (and its twin hrepeat body for a carrier (sampling frequency), which takes the sampling frequency instead of the sampling time, as awgbody(1/fs, ...)) use it and also show the body length, the number of carrier periods and the remaining slip per pass.

Names

The sym of any variable of the formula and any key of its constants, plus the built-in constants pi and e.

Angles are in radians. An expression that cannot be parsed, refers to an unknown name or leaves the domain of a function (a negative sqrt, a division by zero) simply produces no update — the field keeps its previous value instead of showing an error.

A two-variable converter between a vacuum wavelength and a frequency, filed under a new Optics branch of the tree. Either field can be made the output by pressing its = button:

{
  "formulas": [
    {
      "group": "Optics",
      "name": "Wavelength and frequency",
      "help": "Vacuum wavelength against frequency.",
      "constants": { "c": 2.99792458e8 },
      "vars": [
        { "sym":"L", "caption":"Wavelength", "unit":"m",  "value":1e-3, "lsd":-9,
          "min":1e-9, "max":1, "minInc":1e-9, "inc":1e-6, "solve":"c/F" },
        { "sym":"F", "caption":"Frequency",  "unit":"Hz", "value":3e11, "lsd":3,
          "min":1e6, "max":1e16, "minInc":1e3, "inc":1e9, "solve":"c/L" }
      ]
    }
  ]
}

A right click on the formula tree opens a menu with three commands:

Command

Action

Save this formula as...

Writes the selected formula to a .json file in exactly the schema described above. This is the convenient way to obtain a working template: save a built-in formula, edit the copy, and append it to cfg\formulas.json.

Save all formulas as...

Writes the whole current list, built-in formulas included, to one file.

Load formulas...

Reads a .json file and appends every valid formula to the running list; the number added is reported. The merge is session-only — cfg\formulas.json is not modified, so the formulas are gone at the next start unless they are also written into that file.

Values entered on a panel are not preserved: every formula starts again from the value given in its definition.

See also

Main Menu and Toolbar, Unified Edit Control, GUI Map